<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>HK Ties &#187; Tilt-up &amp; Precast Products</title>
	<atom:link href="http://www.hkties.com/category/tilt-up-and-precast-products/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.hkties.com</link>
	<description>Insulated Concrete Sandwich Panel Wall Ties</description>
	<lastBuildDate>Thu, 22 Oct 2009 05:19:53 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=abc</generator>
		<item>
		<title>Standard 8&#8243; Tie (ST200)</title>
		<link>http://www.hkties.com/standard-8-tie-st200/</link>
		<comments>http://www.hkties.com/standard-8-tie-st200/#comments</comments>
		<pubDate>Tue, 18 Nov 2008 05:37:54 +0000</pubDate>
		<dc:creator>HK Ties</dc:creator>
				<category><![CDATA[Tilt-up & Precast Products]]></category>

		<guid isPermaLink="false">http://www.hkties.com/?p=95</guid>
		<description><![CDATA[HK™ Standard Low-Conductivity Wall Tie for 8-Inch Insulation. Item Number: 283441 Product: 8-inch tie for insulated concrete sandwich panels. Applications: Pre-cast, pre-stressed, and tilt-up. Fascia may be supported or unsupported up to 4 inches thick. Insulation Thickness: 8 in. /200 mm Tie length: 11.38 in. /289 mm Embedment Depth: 1.5 in. /38 mm Dia. through [...]]]></description>
			<content:encoded><![CDATA[<p>HK™ Standard Low-Conductivity Wall Tie for 8-Inch Insulation.<br />
Item Number: 283441</p>
<table class="productSpec" border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="30%" valign="top">Product:</td>
<td width="70%" valign="top">8-inch tie for insulated concrete sandwich panels.</td>
</tr>
<tr class="row2">
<td valign="top">Applications:</td>
<td valign="top">Pre-cast, pre-stressed, and tilt-up.  Fascia may be supported or unsupported up to 4 inches thick.</td>
</tr>
<tr>
<td valign="top">Insulation Thickness:</td>
<td valign="top">8 in. /200 mm</td>
</tr>
<tr class="row2">
<td valign="top">Tie length:</td>
<td valign="top">11.38 in. /289 mm</td>
</tr>
<tr>
<td valign="top">Embedment Depth:</td>
<td valign="top">1.5 in. /38 mm</td>
</tr>
<tr class="row2">
<td valign="top">Dia. through Foam:</td>
<td valign="top">0.75 in. /19 mm</td>
</tr>
<tr>
<td valign="top">Fire Performance:</td>
<td valign="top">Resist 300-lb tension load for over 90 minutes when fire tested per Section 7.4.3 of ASTM E1512-01.</td>
</tr>
<tr class="row2">
<td valign="top">Insulation thickness:</td>
<td valign="top">8 in. /200 mm</td>
</tr>
<tr>
<td valign="top">Fascia Thickness:</td>
<td valign="top">2 to 4 in. / 50 to 100mm</td>
</tr>
<tr class="row2">
<td valign="top">Tensile Strength:</td>
<td valign="top">2,300 lb/10.23 kN</td>
</tr>
<tr>
<td valign="top">Pullout Strength:</td>
<td valign="top">2.300 lb/10.23 kN</td>
</tr>
<tr class="row2">
<td valign="top">Panel Shear/tie:</td>
<td valign="top">1,000 lb/4.44 kN</td>
</tr>
<tr>
<td valign="top">Alkaline Resistance:</td>
<td valign="top">Excellent <sup>1</sup></td>
</tr>
<tr class="row2">
<td valign="top">Impact Resistance:</td>
<td valign="top">Excellent <sup>2</sup></td>
</tr>
<tr>
<td valign="top">Thermal Conductivity:</td>
<td valign="top">
<p style="line-height: 150%; margin-top: 0pt; margin-bottom: 0pt;">2.42 Btu-in/hr ft<sup>2</sup>ºF</p>
<p style="line-height: 150%; margin-top: 0pt; margin-bottom: 0pt;">0.35 WmºK</p>
</td>
</tr>
<tr class="row2">
<td colspan="2" valign="top">See installation instructions (Pub. No.  HK-ST-II) before using.<br />
1 Base resin testing showed no change in properties when exposed to Alkalis.<br />
2 The un-notched Izod Impact testing of the base resin yielded no break.</td>
</tr>
</tbody>
</table>
]]></content:encoded>
			<wfw:commentRss>http://www.hkties.com/standard-8-tie-st200/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Standard 6&#8243; Tie (ST150)</title>
		<link>http://www.hkties.com/standard-6-tie-st150/</link>
		<comments>http://www.hkties.com/standard-6-tie-st150/#comments</comments>
		<pubDate>Tue, 18 Nov 2008 05:35:02 +0000</pubDate>
		<dc:creator>HK Ties</dc:creator>
				<category><![CDATA[Tilt-up & Precast Products]]></category>

		<guid isPermaLink="false">http://www.hkties.com/?p=92</guid>
		<description><![CDATA[HK™ Standard Low-Conductivity Wall Tie for 6-Inch Insulation. Item Number: 283440 Product: 6-inch tie for insulated concrete sandwich panels. Applications: Pre-cast, pre-stressed, and tilt-up. Fascia may be supported or unsupported up to 4 inches thick. Insulation Thickness: 6 in. /150 mm Tie length: 9.25 in. /235 mm Embedment Depth: 1.5 in. /38 mm Dia. through [...]]]></description>
			<content:encoded><![CDATA[<p>HK™ Standard Low-Conductivity Wall Tie for 6-Inch Insulation.<br />
Item Number: 283440</p>
<table class="productSpec" border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="30%" valign="top">Product:</td>
<td width="70%" valign="top">6-inch tie for insulated concrete sandwich panels.</td>
</tr>
<tr class="row2">
<td valign="top">Applications:</td>
<td valign="top">Pre-cast, pre-stressed, and tilt-up.  Fascia may be supported or unsupported up to 4 inches thick.</td>
</tr>
<tr>
<td valign="top">Insulation Thickness:</td>
<td valign="top">6 in. /150 mm</td>
</tr>
<tr class="row2">
<td valign="top">Tie length:</td>
<td valign="top">9.25 in. /235 mm</td>
</tr>
<tr>
<td valign="top">Embedment Depth:</td>
<td valign="top">1.5 in. /38 mm</td>
</tr>
<tr class="row2">
<td valign="top">Dia. through Foam:</td>
<td valign="top">0.57 in. /14.5 mm</td>
</tr>
<tr>
<td valign="top">Fire Performance:</td>
<td valign="top">Resist 300-lb tension load for over 90 minutes when fire tested per Section 7.4.3 of ASTM E1512-01.</td>
</tr>
<tr class="row2">
<td valign="top">Insulation thickness:</td>
<td valign="top">6 in. /150 mm</td>
</tr>
<tr>
<td valign="top">Fascia Thickness:</td>
<td valign="top">2 to 4 in. / 50 to 100mm</td>
</tr>
<tr class="row2">
<td valign="top">Tensile Strength:</td>
<td valign="top">1,500 lb/6.67kN</td>
</tr>
<tr>
<td valign="top">Pullout Strength:</td>
<td valign="top">1,500 lb/6.67kN</td>
</tr>
<tr class="row2">
<td valign="top">Panel Shear/tie:</td>
<td valign="top">500 lb/2.22 kN</td>
</tr>
<tr>
<td valign="top">Alkaline Resistance:</td>
<td valign="top">Excellent <sup>1</sup></td>
</tr>
<tr class="row2">
<td valign="top">Impact Resistance:</td>
<td valign="top">Excellent <sup>2</sup></td>
</tr>
<tr>
<td valign="top">Thermal Conductivity:</td>
<td valign="top">
<p style="line-height: 150%; margin-top: 0pt; margin-bottom: 0pt;">2.42 Btu-in/hr ft<sup>2</sup>ºF</p>
<p style="line-height: 150%; margin-top: 0pt; margin-bottom: 0pt;">0.35 WmºK</p>
</td>
</tr>
<tr class="row2">
<td colspan="2" valign="top">See installation instructions (Pub. No.  HK-ST-II) before using.<br />
1 Base resin testing showed no change in properties when exposed to Alkalis.<br />
2 The un-notched Izod Impact testing of the base resin yielded no break.</td>
</tr>
</tbody>
</table>
]]></content:encoded>
			<wfw:commentRss>http://www.hkties.com/standard-6-tie-st150/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Standard 4&#8243; Tie (ST100)</title>
		<link>http://www.hkties.com/standard-4-tie-st100/</link>
		<comments>http://www.hkties.com/standard-4-tie-st100/#comments</comments>
		<pubDate>Tue, 18 Nov 2008 05:32:28 +0000</pubDate>
		<dc:creator>HK Ties</dc:creator>
				<category><![CDATA[Tilt-up & Precast Products]]></category>

		<guid isPermaLink="false">http://www.hkties.com/?p=89</guid>
		<description><![CDATA[HK™ Standard Low-Conductivity Wall Tie for 4-Inch Insulation. Item Number: 283439 Product: 4-inch tie for insulated concrete sandwich panels. Applications: Pre-cast, pre-stressed, and tilt-up. Fascia may be supported or unsupported up to 4 inches thick. Insulation Thickness: 4 in. /100 mm Tie length: 7.25 in. /184 mm Embedment Depth: 1.5 in. /38 mm Dia. through [...]]]></description>
			<content:encoded><![CDATA[<p>HK™ Standard Low-Conductivity Wall Tie for 4-Inch Insulation.<br />
Item Number: 283439</p>
<table class="productSpec" border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="30%" valign="top">Product:</td>
<td width="70%" valign="top">4-inch tie for insulated concrete sandwich panels.</td>
</tr>
<tr class="row2">
<td valign="top">Applications:</td>
<td valign="top">Pre-cast, pre-stressed, and tilt-up.  Fascia may be supported or unsupported up to 4 inches thick.</td>
</tr>
<tr>
<td valign="top">Insulation Thickness:</td>
<td valign="top">4 in. /100 mm</td>
</tr>
<tr class="row2">
<td valign="top">Tie length:</td>
<td valign="top">7.25 in. /184 mm</td>
</tr>
<tr>
<td valign="top">Embedment Depth:</td>
<td valign="top">1.5 in. /38 mm</td>
</tr>
<tr class="row2">
<td valign="top">Dia. through Foam:</td>
<td valign="top">0.57 in. /14.5 mm</td>
</tr>
<tr>
<td valign="top">Fire Performance:</td>
<td valign="top">Resist 300-lb tension load for over 90 minutes when fire tested per Section 7.4.3 of ASTM E1512-01.</td>
</tr>
<tr>
<td valign="top">Fascia Thickness:</td>
<td valign="top">2 to 4 in. / 50 to 100 mm</td>
</tr>
<tr class="row2">
<td valign="top">Tensile Strength:</td>
<td valign="top">1,500 lb/6.67 kN</td>
</tr>
<tr>
<td valign="top">Pullout Strength:</td>
<td valign="top">1,500 lb/6.67 kN</td>
</tr>
<tr class="row2">
<td valign="top">Panel Shear/tie:</td>
<td valign="top">500 lb/2.22 kN</td>
</tr>
<tr>
<td valign="top">Alkaline Resistance:</td>
<td valign="top">Excellent <sup>1</sup></td>
</tr>
<tr class="row2">
<td valign="top">Impact Resistance:</td>
<td valign="top">Excellent <sup>2</sup></td>
</tr>
<tr>
<td valign="top">Thermal Conductivity:</td>
<td valign="top">
<p style="line-height: 150%; margin-top: 0pt; margin-bottom: 0pt;">2.42 Btu-in/hr ft<sup>2</sup>ºF</p>
<p style="line-height: 150%; margin-top: 0pt; margin-bottom: 0pt;">0.35 WmºK</p>
</td>
</tr>
<tr class="row2">
<td colspan="2" valign="top">See installation instructions (Pub. No.  HK-ST-II) before using.<br />
1 Base resin testing showed no change in properties when exposed to Alkalis.<br />
2 The un-notched Izod Impact testing of the base resin yielded no break.</td>
</tr>
</tbody>
</table>
]]></content:encoded>
			<wfw:commentRss>http://www.hkties.com/standard-4-tie-st100/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Standard 3&#8243; Tie (ST75)</title>
		<link>http://www.hkties.com/standard-3-tie-st75/</link>
		<comments>http://www.hkties.com/standard-3-tie-st75/#comments</comments>
		<pubDate>Tue, 18 Nov 2008 05:30:07 +0000</pubDate>
		<dc:creator>HK Ties</dc:creator>
				<category><![CDATA[Tilt-up & Precast Products]]></category>

		<guid isPermaLink="false">http://www.hkties.com/?p=86</guid>
		<description><![CDATA[HK™ Standard Low-Conductivity Wall Tie for 3-Inch Insulation. Item Number: 283429 Product: 3-inch tie for insulated concrete sandwich panels. Applications: Pre-cast, pre-stressed, and tilt-up. Fascia may be supported or unsupported up to 4 inches thick. Insulation Thickness: 3 in. /75 mm Tie length: 6.25 in. /160 mm Embedment Depth: 1.5 in. /38 mm Dia. through [...]]]></description>
			<content:encoded><![CDATA[<p>HK™ Standard Low-Conductivity Wall Tie for 3-Inch Insulation.<br />
Item Number: 283429</p>
<table class="productSpec" border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="30%" valign="top">Product:</td>
<td width="70%" valign="top">3-inch tie for insulated concrete sandwich panels.</td>
</tr>
<tr class="row2">
<td valign="top">Applications:</td>
<td valign="top">Pre-cast, pre-stressed, and tilt-up.  Fascia may be supported or unsupported up to 4 inches thick.</td>
</tr>
<tr>
<td valign="top">Insulation Thickness:</td>
<td valign="top">3 in. /75 mm</td>
</tr>
<tr class="row2">
<td valign="top">Tie length:</td>
<td valign="top">6.25 in. /160 mm</td>
</tr>
<tr>
<td valign="top">Embedment Depth:</td>
<td valign="top">1.5 in. /38 mm</td>
</tr>
<tr class="row2">
<td valign="top">Dia. through Foam:</td>
<td valign="top">0.57 in. /14.5 mm</td>
</tr>
<tr>
<td valign="top">Fire Performance:</td>
<td valign="top">Resist 300-lb tension load for over 90 minutes when fire tested per Section 7.4.3 of ASTM E1512-01.</td>
</tr>
<tr class="row2">
<td valign="top">Insulation thickness:</td>
<td valign="top">3 in. /75 mm</td>
</tr>
<tr>
<td valign="top">Fascia Thickness:</td>
<td valign="top">2 to 4 in. / 50 to 100 mm</td>
</tr>
<tr class="row2">
<td valign="top">Tensile Strength:</td>
<td valign="top">1,500 lb/6.67 kN</td>
</tr>
<tr>
<td valign="top">Pullout Strength:</td>
<td valign="top">1,500 lb/6.67 kN</td>
</tr>
<tr class="row2">
<td valign="top">Panel Shear/tie:</td>
<td valign="top">500 lb/2.22 kN</td>
</tr>
<tr>
<td valign="top">Alkaline Resistance:</td>
<td valign="top">Excellent <sup>1</sup></td>
</tr>
<tr class="row2">
<td valign="top">Impact Resistance:</td>
<td valign="top">Excellent <sup>2</sup></td>
</tr>
<tr>
<td valign="top">Thermal Conductivity:</td>
<td valign="top">
<p style="line-height: 150%; margin-top: 0pt; margin-bottom: 0pt;">2.42 Btu-in/hr ft<sup>2</sup>ºF</p>
<p style="line-height: 150%; margin-top: 0pt; margin-bottom: 0pt;">0.35 WmºK</p>
</td>
</tr>
<tr class="row2">
<td colspan="2" valign="top">See installation instructions (Pub. No.  HK-ST-II) before using.<br />
1 Base resin testing showed no change in properties when exposed to Alkalis.<br />
2 The un-notched Izod Impact testing of the base resin yielded no break.</td>
</tr>
</tbody>
</table>
]]></content:encoded>
			<wfw:commentRss>http://www.hkties.com/standard-3-tie-st75/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Standard 2.5&#8243; Tie (ST60)</title>
		<link>http://www.hkties.com/standard-25-tie-st60/</link>
		<comments>http://www.hkties.com/standard-25-tie-st60/#comments</comments>
		<pubDate>Tue, 18 Nov 2008 05:23:24 +0000</pubDate>
		<dc:creator>HK Ties</dc:creator>
				<category><![CDATA[Tilt-up & Precast Products]]></category>

		<guid isPermaLink="false">http://www.hkties.com/?p=83</guid>
		<description><![CDATA[HK™ Standard Low-Conductivity Wall Tie for 2.5-Inch Insulation. Item Number: 283425 Product: 2.5-inch tie for insulated concrete sandwich panels. Applications: Pre-cast, pre-stressed, and tilt-up. Fascia may be supported or unsupported up to 4 inches thick. Insulation Thickness: 2.5 in. /64 mm Tie length: 5.75 in. /146 mm Embedment Depth: 1.5 in. /38 mm Dia. through [...]]]></description>
			<content:encoded><![CDATA[<p>HK™ Standard Low-Conductivity Wall Tie for 2.5-Inch Insulation.<br />
Item Number: 283425</p>
<table class="productSpec" border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="30%" valign="top">Product:</td>
<td width="70%" valign="top">2.5-inch tie for insulated concrete sandwich panels.</td>
</tr>
<tr class="row2">
<td valign="top">Applications:</td>
<td valign="top">Pre-cast, pre-stressed, and tilt-up.  Fascia may be supported or unsupported up to 4 inches thick.</td>
</tr>
<tr>
<td valign="top">Insulation Thickness:</td>
<td valign="top">2.5 in. /64 mm</td>
</tr>
<tr class="row2">
<td valign="top">Tie length:</td>
<td valign="top">5.75 in. /146 mm</td>
</tr>
<tr>
<td valign="top">Embedment Depth:</td>
<td valign="top">1.5 in. /38 mm</td>
</tr>
<tr class="row2">
<td valign="top">Dia. through Foam:</td>
<td valign="top">0.5 in. /12.5 mm</td>
</tr>
<tr>
<td valign="top">Fire Performance:</td>
<td valign="top">Resist 300-lb tension load for over 90 minutes when fire tested per Section 7.4.3 of ASTM E1512-01.</td>
</tr>
<tr class="row2">
<td valign="top">Insulation thickness:</td>
<td valign="top">2.5 in. /64 mm</td>
</tr>
<tr>
<td valign="top">Fascia Thickness:</td>
<td valign="top">2 to 4 in. / 50 to 100mm</td>
</tr>
<tr class="row2">
<td valign="top">Tensile Strength:</td>
<td valign="top">1,100 lb/4.89kN</td>
</tr>
<tr>
<td valign="top">Pullout Strength:</td>
<td valign="top">1,100 lb/4.89kN</td>
</tr>
<tr class="row2">
<td valign="top">Panel Shear/tie:</td>
<td valign="top">400 lb/1.78 kN</td>
</tr>
<tr>
<td valign="top">Alkaline Resistance:</td>
<td valign="top">Excellent <sup>1</sup></td>
</tr>
<tr class="row2">
<td valign="top">Impact Resistance:</td>
<td valign="top">Excellent <sup>2</sup></td>
</tr>
<tr>
<td valign="top">Thermal Conductivity:</td>
<td valign="top">
<p style="line-height: 150%; margin-top: 0pt; margin-bottom: 0pt;">2.42 Btu-in/hr ft<sup>2</sup>ºF</p>
<p style="line-height: 150%; margin-top: 0pt; margin-bottom: 0pt;">0.35 WmºK</p>
</td>
</tr>
<tr class="row2">
<td colspan="2" valign="top">See installation instructions (Pub. No.  HK-ST-II) before using.<br />
1 Base resin testing showed no change in properties when exposed to Alkalis.<br />
2 The un-notched Izod Impact testing of the base resin yielded no break.</td>
</tr>
</tbody>
</table>
]]></content:encoded>
			<wfw:commentRss>http://www.hkties.com/standard-25-tie-st60/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Standard 2&#8243; Tie (ST50)</title>
		<link>http://www.hkties.com/standard-2-tie-st50/</link>
		<comments>http://www.hkties.com/standard-2-tie-st50/#comments</comments>
		<pubDate>Tue, 18 Nov 2008 05:17:43 +0000</pubDate>
		<dc:creator>HK Ties</dc:creator>
				<category><![CDATA[Tilt-up & Precast Products]]></category>

		<guid isPermaLink="false">http://www.hkties.com/?p=77</guid>
		<description><![CDATA[HK™ Standard Low-Conductivity Wall Tie for 2-Inch Insulation. Item Number: 283424 Product: 2-inch Tie for insulated concrete sandwich panels. Applications: Pre-cast, pre-stressed, and tilt-up. Fascia may be supported or unsupported up to 4 inches thick. Insulation Thickness: 2 in. /50 mm Tie length: 5.31 in. /135 mm Embedment Depth: 1.5 in. /38 mm Dia. through [...]]]></description>
			<content:encoded><![CDATA[<p>HK™ Standard Low-Conductivity Wall Tie for 2-Inch Insulation.<br />
Item Number: 283424</p>
<table class="productSpec" border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="30%" valign="top">Product:</td>
<td width="70%" valign="top">2-inch Tie for insulated concrete sandwich panels.</td>
</tr>
<tr class="row2">
<td valign="top">Applications:</td>
<td valign="top">Pre-cast, pre-stressed, and tilt-up.  Fascia may be supported or unsupported up to 4 inches thick.</td>
</tr>
<tr>
<td valign="top">Insulation Thickness:</td>
<td valign="top">2 in. /50 mm</td>
</tr>
<tr class="row2">
<td valign="top">Tie length:</td>
<td valign="top">5.31 in. /135 mm</td>
</tr>
<tr>
<td valign="top">Embedment Depth:</td>
<td valign="top">1.5 in. /38 mm</td>
</tr>
<tr class="row2">
<td valign="top">Dia. through Foam:</td>
<td valign="top">0.5 in. /12.5 mm</td>
</tr>
<tr>
<td valign="top">Fire Performance:</td>
<td valign="top">Resist 300-lb tension load for over 90 minutes when fire tested per Section 7.4.3 of ASTM E1512-01.</td>
</tr>
<tr class="row2">
<td valign="top">Insulation thickness:</td>
<td valign="top">2 in. /50 mm</td>
</tr>
<tr>
<td valign="top">Fascia Thickness:</td>
<td valign="top">2 to 4 in. / 50 to 100 mm</td>
</tr>
<tr class="row2">
<td valign="top">Tensile Strength:</td>
<td valign="top">1,100 lb/4.89 kN</td>
</tr>
<tr>
<td valign="top">Pullout Strength:</td>
<td valign="top">1,100 lb/4.89 kN</td>
</tr>
<tr class="row2">
<td valign="top">Panel Shear/tie:</td>
<td valign="top">500 lb/2.22 kN</td>
</tr>
<tr>
<td valign="top">Alkaline Resistance:</td>
<td valign="top">Excellent <sup>1</sup></td>
</tr>
<tr class="row2">
<td valign="top">Impact Resistance:</td>
<td valign="top">Excellent <sup>2</sup></td>
</tr>
<tr>
<td valign="top">Thermal Conductivity:</td>
<td valign="top">
<p style="line-height: 150%; margin-top: 0pt; margin-bottom: 0pt;">2.42 Btu-in/hr ft<sup>2</sup>ºF</p>
<p style="line-height: 150%; margin-top: 0pt; margin-bottom: 0pt;">0.35 WmºK</p>
</td>
</tr>
<tr class="row2">
<td colspan="2" valign="top">See installation instructions (Pub. No.  HK-ST-II) before using.<br />
1 Base resin testing showed no change in properties when exposed to Alkalis.<br />
2 The un-notched Izod Impact testing of the base resin yielded no break.</td>
</tr>
</tbody>
</table>
]]></content:encoded>
			<wfw:commentRss>http://www.hkties.com/standard-2-tie-st50/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Double-Prong 1.5&#8243; Tie (DP38)</title>
		<link>http://www.hkties.com/double-prong-15-tie-dp38/</link>
		<comments>http://www.hkties.com/double-prong-15-tie-dp38/#comments</comments>
		<pubDate>Sun, 16 Nov 2008 22:00:40 +0000</pubDate>
		<dc:creator>HK Ties</dc:creator>
				<category><![CDATA[Tilt-up & Precast Products]]></category>

		<guid isPermaLink="false">http://www.hkties.com/?p=73</guid>
		<description><![CDATA[HK™ Double-Prong Low-Conductivity Wall Tie Item Number: 313813 Product: 1.5-inch Tie for insulated concrete sandwich panels. Applications: Pre-cast, pre-stressed, and tilt-up. Fascia may be supported or unsupported up to 3 inches thick or supported up to 4 inches thick. Insulation Thickness: 1.5 in. /38 mm Tie length: 4.75 in. /121 mm Embedment Depth: 1.75 in. [...]]]></description>
			<content:encoded><![CDATA[<p>HK™ Double-Prong Low-Conductivity Wall Tie<br />
Item Number: 313813</p>
<table class="productSpec" border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="30%" valign="top">Product:</td>
<td width="70%" valign="top">1.5-inch Tie for insulated concrete sandwich panels.</td>
</tr>
<tr class="row2">
<td valign="top">Applications:</td>
<td valign="top">Pre-cast, pre-stressed, and tilt-up. Fascia may be supported or unsupported up to 3 inches thick or supported up to 4 inches thick.</td>
</tr>
<tr>
<td valign="top">Insulation Thickness:</td>
<td valign="top">1.5 in. /38 mm</td>
</tr>
<tr class="row2">
<td valign="top">Tie length:</td>
<td valign="top">4.75 in. /121 mm</td>
</tr>
<tr>
<td valign="top">Embedment Depth:</td>
<td valign="top">1.75 in. /44 mm and 1.50 in./38 mm</td>
</tr>
<tr class="row2">
<td valign="top">Dia. through Foam:</td>
<td valign="top">2 x 0.354 in./2 x 9.0mm</td>
</tr>
<tr>
<td valign="top">Fire Performance:</td>
<td valign="top">Resist 300-lb tension load for over 120 minutes when fire tested per Section 7.4.3 of ASTM E1512-01.</td>
</tr>
<tr>
<td valign="top">Fascia Thickness:</td>
<td valign="top">2 to 4 in. / 50 to 100mm  1,100 lb/4.89kN</td>
</tr>
<tr class="row2">
<td valign="top">Tensile Strength:</td>
<td valign="top">1,100 lb/4.89 kN</td>
</tr>
<tr>
<td valign="top">Pullout Strength:</td>
<td valign="top">1,100 lb/4.89 kN</td>
</tr>
<tr class="row2">
<td valign="top">Panel Shear/tie:</td>
<td valign="top">400 lb/1.78 kN</td>
</tr>
<tr>
<td valign="top">Alkaline Resistance:</td>
<td valign="top">Excellent <sup>1</sup></td>
</tr>
<tr class="row2">
<td valign="top">Impact Resistance:</td>
<td valign="top">Excellent <sup>2</sup></td>
</tr>
<tr>
<td valign="top">Thermal Conductivity:</td>
<td valign="top">2.42 Btu-in/hr-ft<sup>2</sup>ºF<br />
0.35 WmºK</td>
</tr>
<tr class="row2">
<td colspan="2" valign="top">See installation instructions (Pub. No.  HK-ST-II) before using.<br />
1 Base resin testing showed no change in properties when exposed to Alkalis.<br />
2 The un-notched Izod Impact testing of the base resin yielded no break.</td>
</tr>
</tbody>
</table>
]]></content:encoded>
			<wfw:commentRss>http://www.hkties.com/double-prong-15-tie-dp38/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Double-Prong 1.0&#8243; Tie (DP25)</title>
		<link>http://www.hkties.com/double-prong-10-tie-dp25/</link>
		<comments>http://www.hkties.com/double-prong-10-tie-dp25/#comments</comments>
		<pubDate>Sun, 16 Nov 2008 20:36:35 +0000</pubDate>
		<dc:creator>HK Ties</dc:creator>
				<category><![CDATA[Tilt-up & Precast Products]]></category>

		<guid isPermaLink="false">http://www.hkties.com/?p=70</guid>
		<description><![CDATA[HK™ Double-Prong Low-Conductivity Wall Tie Item Number: 313812 Product: 1-inch Tie for insulated concrete sandwich panels. Applications: Pre-cast, pre-stressed, and tilt-up. Fascia may be supported or unsupported up to 3 inches thick or supported up to 4 inches thick. Insulation Thickness: 1 in. /25mm Tie length: 4.25 in. /108 mm Embedment Depth: 1.75 in. /44 [...]]]></description>
			<content:encoded><![CDATA[<p>HK™ Double-Prong Low-Conductivity Wall Tie<br />
Item Number: 313812</p>
<table class="productSpec" border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="30%" valign="top">Product:</td>
<td width="70%" valign="top">1-inch Tie for insulated concrete sandwich panels.</td>
</tr>
<tr class="row2">
<td valign="top">Applications:</td>
<td valign="top">Pre-cast, pre-stressed, and tilt-up. Fascia may be supported or unsupported up to 3 inches thick or supported up to 4 inches thick.</td>
</tr>
<tr>
<td valign="top">Insulation Thickness:</td>
<td valign="top">1 in. /25mm</td>
</tr>
<tr class="row2">
<td valign="top">Tie length:</td>
<td valign="top">4.25 in. /108 mm</td>
</tr>
<tr>
<td valign="top">Embedment Depth:</td>
<td valign="top">1.75 in. /44 mm and 1.50 in./38 mm</td>
</tr>
<tr class="row2">
<td valign="top">Dia. through Foam:</td>
<td valign="top">2 x 0.354 in./2 x 9.0mm</td>
</tr>
<tr>
<td valign="top">Fire Performance:</td>
<td valign="top">Resist 300-lb tension load for over 120 minutes when fire tested per Section 7.4.3 of ASTM E1512-01.</td>
</tr>
<tr>
<td valign="top">Fascia Thickness:</td>
<td valign="top">2 to 4 in. / 50 to 100 mm</td>
</tr>
<tr class="row2">
<td valign="top">Tensile Strength:</td>
<td valign="top">1,100 lb/4.89 kN</td>
</tr>
<tr>
<td valign="top">Pullout Strength:</td>
<td valign="top">1,100 lb/4.89 kN</td>
</tr>
<tr class="row2">
<td valign="top">Panel Shear/tie:</td>
<td valign="top">500 lb/2.22 kN</td>
</tr>
<tr>
<td valign="top">Alkaline Resistance:</td>
<td valign="top">Excellent <sup>1</sup></td>
</tr>
<tr class="row2">
<td valign="top">Impact Resistance:</td>
<td valign="top">Excellent <sup>2</sup></td>
</tr>
<tr>
<td valign="top">Thermal Conductivity:</td>
<td valign="top">2.42 Btu-in/hr-ft<sup>2</sup>ºF<br />
0.35 WmºK</td>
</tr>
<tr class="row2">
<td colspan="2" valign="top">See installation instructions (Pub. No.  HK-ST-II) before using.<br />
1 Base resin testing showed no change in properties when exposed to Alkalis.<br />
2 The un-notched Izod Impact testing of the base resin yielded no break.</td>
</tr>
</tbody>
</table>
]]></content:encoded>
			<wfw:commentRss>http://www.hkties.com/double-prong-10-tie-dp25/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
